The Fluke Biomedical Index 2 SpO2 Simulator is a pulse oximeter simulator used to verify pulse oximeter response across oxygen saturation, pulse rate, perfusion, and motion-related test conditions. This listing includes a charger as stated in the title and is intended for biomedical engineers servicing SpO2 monitoring equipment.

Specifications

  • Model: Fluke Biomedical Index 2 SpO2 Simulator.
  • Instrument type: pulse oximeter / SpO2 simulator.
  • SpO2 simulation range: 35% to 100%.
  • SpO2 resolution: 1%.
  • Pulse rate range: 30 BPM to 250 BPM according to published Fluke Biomedical specifications.
  • Capabilities: optical simulations for complete pulse oximeter testing.
  • Additional functions: arterial wave-amplitude/perfusion scale and tap/shiver motion simulations.
  • Connectivity: RS-232 computer-control capability listed in product documentation.
  • Included accessory note: charger included as stated in listing title; verify exact charger and cables from photos.

Key Features

  • Simulates oxygen saturation and pulse rate for pulse oximeter verification.
  • Supports optical sensor testing rather than only electrical signal checks.
  • Motion simulation helps evaluate oximeter performance under difficult test conditions.
  • Perfusion/amplitude controls support broader test coverage.
  • Useful for biomedical PM and troubleshooting of SpO2 equipment.
  • Computer-control capability supports documented workflows when compatible software is available.

Typical Applications

  • Pulse oximeter preventive maintenance.
  • SpO2 monitor verification.
  • Biomedical engineering troubleshooting.
  • Sensor and probe testing support.
  • Clinical engineering equipment acceptance checks.

The Index 2 is a legacy Fluke Biomedical simulator, so buyers should verify charger condition, battery performance, available sensor/finger accessories, software compatibility, and calibration status. The listing should be used together with photos to confirm the exact configuration supplied.